Read the Beforeitsnews.com story here. Advertise at Before It's News here.
Profile image
By Bradley J Roth
Contributor profile | More stories
Story Views
Now:
Last hour:
Last 24 hours:
Total:

The Magnetic Field of a Single Axon (Part 1)

% of readers think this story is Fact. Add your two cents.


Thirty years ago, John Wikswo and I published The Magnetic Field of a Single Axon: A Comparison of Theory and Experiment (Biophysical Journal, Volume 48, Pages 93-109, 1985). This was my second journal article (and my first as first author). Russ Hobbie and I cite it in Chapter 8 of the 5th edition of Intermediate Physics for Medicine and Biology. I reproduce the introduction below.

“An active nerve axon can be modeled with sufficient accuracy to allow a detailed calculation of the associated magnetic field. Therefore the single axon provides a simple, yet fundamentally important system from which we can test our understanding of the relation between biomagnetic and bioelectric fields. The magnetic field produced by a propagating action potential has been calculated from the transmembrane action potential using the volume conductor model (1). The purpose of this paper is to verify that calculation experimentally. To make an accurate comparison between theory and experiment, we must be careful to correct for all systematic errors present in the data.

To test the volume conductor model it is necessary to measure the transmembrane potential and magnetic field simultaneously. An experiment performed by Wikswo et al. (2) provided preliminary data from a lobster axon, however the electric and magnetic signals were recorded at different positions along the axon and no quantitative comparisons were made between theory and experiment. In the experiment reported here, these limitations were overcome and improved instrumentation was used (3-5).”

As the introduction notes, the volume conductor model was described in reference (1), which is an article by Jim Woosley, Wikswo and myself (The Magnetic Field of a Single Axon: A Volume Conductor Model, Mathematical Biosciences, Volume 76, Pages 1-36, 1985). I have discussed the calculation of the magnetic field previously in this blog, so today I will restrict myself to the experiment.

I was not the first to measure the magnetic field of a single axon. Wikswo’s student, J. C. Palmer, had made preliminary measurements using a lobster axon; reference (2) is to their earlier paper. One of the first tasks Wikswo gave me as a new graduate student was to reproduce and improve Palmer’s experiment, which meant I had to learn how to dissect and isolate a nerve. Lobsters were too expensive for me to practice with so I first dissected cheaper crayfish nerves; our plan was that once I had gotten good at crayfish we would switch to the larger lobster. I eventually became skilled enough in working with the crayfish nerve, and the data we obtained was good enough, that we never bothered with the lobsters.

I had to learn several techniques before I could perform the experiment. I recorded the transmembrane potential using a glass microelectrode. The electrode is made starting with a hollow glass tube, about 1 mm in diameter. We had a commercial microelectrode puller, but it was an old design and had poor control over timing. So, one of my jobs was to design the timing circuitry (see here for more details). The glass would be warmed by a small wire heating element (much like you have in a toaster, but smaller), and once the glass was soft the machine would pull the two ends of the tube apart. The hot glass stretched and eventually broke, providing two glass tubes with long, tapering tips with a hole at the narrow end of about 1 micron diameter. I would then backfill these tubes with 2 Molar potassium citrate. The concentration was so high that when I occasionally forgot to clean up after an experiment I would comeback the next day and find the water had evaporated leaving impressive, large crystals. The back end of the glass tube would be put into a plexiglass holder that connected the conducting fluid to a silver-chloride electrode, and then to an amplifier.

One limitation of these measurements was the capacitance between the microelectrode and the perfusing bath. Because the magnetic measurements required that the nerve be completely immersed in saline, I could not reduce the stray capacitance by lowering the height of the bath. This capacitance severely reduced the rate of rise of the action potential, and to correct for it we used “negative capacitance”. We applied a square voltage pulse to the bath, and measured the microelectrode signal. We then adjusted the frequency compensation knob on the amplifier (basically, a differentiator) until the resulting microelectrode signal was a square pulse. That was the setting we used for measuring the action potential. Whenever I changed the position of the electrode or the depth of the bath, I had to recalibrate the negative capacitance.

To record the transmembrane potential, I would poke the axon (easy to see under a dissecting microscope) with a microelectrode. Often the tip of the electrode would not enter the axon, so I would tap on the lab bench creating a vibration that was just sufficient to drive the electrode through the membrane. Usually I had the output of the microelectrode amplifier go to a device that output current with a frequency that varied with the microelectrode voltage. I would put this current through a speaker, so I could listen for when the microelectrode tip was successfully inside the axon because the DC potential would drop by about 70 mV (the axon’s resting potential) and therefore the pitch of the speaker would suddenly drop.

Next week I will continue this story, describing how we measured the magnetic field.


Source: http://hobbieroth.blogspot.com/2015/10/the-magnetic-field-of-single-axon-part-1.html


Before It’s News® is a community of individuals who report on what’s going on around them, from all around the world.

Anyone can join.
Anyone can contribute.
Anyone can become informed about their world.

"United We Stand" Click Here To Create Your Personal Citizen Journalist Account Today, Be Sure To Invite Your Friends.

Please Help Support BeforeitsNews by trying our Natural Health Products below!


Order by Phone at 888-809-8385 or online at https://mitocopper.com M - F 9am to 5pm EST

Order by Phone at 866-388-7003 or online at https://www.herbanomic.com M - F 9am to 5pm EST

Order by Phone at 866-388-7003 or online at https://www.herbanomics.com M - F 9am to 5pm EST


Humic & Fulvic Trace Minerals Complex - Nature's most important supplement! Vivid Dreams again!

HNEX HydroNano EXtracellular Water - Improve immune system health and reduce inflammation.

Ultimate Clinical Potency Curcumin - Natural pain relief, reduce inflammation and so much more.

MitoCopper - Bioavailable Copper destroys pathogens and gives you more energy. (See Blood Video)

Oxy Powder - Natural Colon Cleanser!  Cleans out toxic buildup with oxygen!

Nascent Iodine - Promotes detoxification, mental focus and thyroid health.

Smart Meter Cover -  Reduces Smart Meter radiation by 96%! (See Video).

Report abuse

    Comments

    Your Comments
    Question   Razz  Sad   Evil  Exclaim  Smile  Redface  Biggrin  Surprised  Eek   Confused   Cool  LOL   Mad   Twisted  Rolleyes   Wink  Idea  Arrow  Neutral  Cry   Mr. Green

    MOST RECENT
    Load more ...

    SignUp

    Login

    Newsletter

    Email this story
    Email this story

    If you really want to ban this commenter, please write down the reason:

    If you really want to disable all recommended stories, click on OK button. After that, you will be redirect to your options page.