Can refurbished solid walls reach 0.3 U?

% of readers think this story is Fact. Add your two cents.


Building Regulations in the UK have been interpreted for years as demanding that refurbished walls need to meet a U value of 0.3. Products have therefore been designed using BR443 and BS5250:2011 to comply with this.

Unfortunately, even BS5250:2011 states that it is no good at modelling ‘in service’ situations. The whole model is based on water vapour only, no account for liquid water at all. Not so good when you are dealing with breathable walls (AKA virtually all walls built before 1919!)

BR443 is the calculation matrix that gives us U values. This, though, has been shown in virtually all cases to be very inaccurate when assessing solid walls. Caroline Rye’s work has clearly shown wide discrepancies with measured in-situ U values with predicted ones from common U value calculators. DECC is taking this very seriously and the STBA has been affecting Government thinking thanks to this key research.

So, given that the tools that we have to use to calculate solid wall U values are, in effect, useless and that the unintended consequences of using non-breathable insulation materials can be as severe as structural failure, what can we do?

Well there is a little used get-out clause in Part L1B of the Building Regulations.

Part L1B states:
Dwellings Exempt from Energy Efficiency Requirements
3.8 Historic and traditional buildings where special considerations may apply
c. buildings of traditional construction with permeable fabric that both absorbs and readily allows the evaporation of moisture

It goes on to say that you should aim to improve the energy efficiency as far as is reasonably practicable and it should not increase the long term risk to the building fabric. It also states that you should make provisions to enable the fabric of the building to ‘breathe’ to control moisture and reduce the decay problems.

The document also points you towards your local conservation officer for advice. So I would recommend sending them the STBA report on Responsible Retrofit first!

Dr Jo Hoppers work on thermal insulation seems to suggest that the thermal bridging associated with wall insulation is such that even the best detailed Passive House refurbishments will be hard pressed to reach U values much below 0.3, so standard installations will be virtaully impossible to achieve these types of figures.

However, within this doom and gloom is there a ray of hope?

Yes!

The U value research by a growing number of people and orgs (inc BRE) show that the U value of these old solid walls are radically better than predicted, so you might already have a well performing wall! The U value of your wall might correspond to the types tested by the STBA / SPAB by Dr Rye, so it is worth checking your wall structure against the research findings. You can then use this to show your Conservation Officer as well.

Good luck!


Source: http://ecohomecentre.blogspot.com/2013/06/can-refurbished-solid-walls-reach-03-u.html


Before It’s News® is a community of individuals who report on what’s going on around them, from all around the world.

Anyone can join.
Anyone can contribute.
Anyone can become informed about their world.

"United We Stand" Click Here To Create Your Personal Citizen Journalist Account Today, Be Sure To Invite Your Friends.

Please Help Support BeforeitsNews by trying our Natural Health Products below!


Order by Phone at 888-809-8385 or online at https://mitocopper.com M - F 9am to 5pm EST

Order by Phone at 866-388-7003 or online at https://www.herbanomic.com M - F 9am to 5pm EST

Order by Phone at 866-388-7003 or online at https://www.herbanomics.com M - F 9am to 5pm EST


Humic & Fulvic Trace Minerals Complex - Nature's most important supplement! Vivid Dreams again!

HNEX HydroNano EXtracellular Water - Improve immune system health and reduce inflammation.

Ultimate Clinical Potency Curcumin - Natural pain relief, reduce inflammation and so much more.

MitoCopper - Bioavailable Copper destroys pathogens and gives you more energy. (See Blood Video)

Oxy Powder - Natural Colon Cleanser!  Cleans out toxic buildup with oxygen!

Nascent Iodine - Promotes detoxification, mental focus and thyroid health.

Smart Meter Cover -  Reduces Smart Meter radiation by 96%! (See Video).

Report abuse

    Comments

    Your Comments
    Question   Razz  Sad   Evil  Exclaim  Smile  Redface  Biggrin  Surprised  Eek   Confused   Cool  LOL   Mad   Twisted  Rolleyes   Wink  Idea  Arrow  Neutral  Cry   Mr. Green

    MOST RECENT
    Load more ...

    SignUp

    Login

    Newsletter

    Email this story
    Email this story

    If you really want to ban this commenter, please write down the reason:

    If you really want to disable all recommended stories, click on OK button. After that, you will be redirect to your options page.